View Energy Savings

About this task

Perform this procedure to view the amount of switch capacity and PoE power being saved on the units.

Procedure

  1. In the navigation pane, expand Configuration > Power Management.
  2. Select Energy Saver.
  3. Select the Energy Savings tab.

Energy Savings Field Descriptions

Use the data in the following table to use the Energy Savings tab.

Name

Description

UnitIndex

Specifies the unit number.

UnitSavings(1/10 watts)

Specifies the amount of switch capacity power being saved on the specific unit.

PoeSavings(1/10 watts)

Specifies the amount of PoE power being saved on the specific unit.